Related illustrations
0556Neutral and ground separated in subpanels
· p. 94
The illustration shows an open subpanel supplied by red and black hot conductors, a white neutral conductor, and a green grounding conductor from the main panel. Circuit breakers connect to the interior bus bars, with ne
0574Neutral and ground separated in subpanels
· p. 97
The illustration shows an electrical subpanel with its cover removed, exposing circuit breakers, bus bars, neutral terminals, and grounding terminals. Red and black feeder conductors from the main panel supply the bus ba
0575Neutral and ground separated in subpanels
· p. 97
The illustration shows an electrical subpanel with its cover removed, exposing circuit breakers, bus bars, neutral bars, and grounding terminals. Feeder conductors enter from the main panel, with the green ground wire bo
0571Subpanel wiring - no separate disconnect switch
· p. 96
The illustration shows a main electrical distribution panel supplying a 60 amp subpanel through an 8 gauge copper feeder. The feeder is connected directly to the main panel bus bars rather than through a dedicated feeder
0573Subpanel wiring - disconnect near main panel
· p. 97
The illustration shows a main electrical panel supplying a subpanel through a separate 40-amp breaker located near the main panel. An 8 gauge copper feeder connects directly to the main panel bus bars and passes through
0572Subpanel wiring - disconnect near subpanel
· p. 97
The illustration shows a main distribution panel feeding a subpanel through an 8 gauge copper feed wire connected directly to the main panel bus bars. A separate 40-amp breaker is located beside the subpanel, at the rece