Related illustrations
1210Discharging condensate
· p. 212
A cross section shows an A-shaped evaporator coil in the supply plenum above a furnace heat exchanger and blower. Arrows show return air entering the blower compartment and supply air moving upward through the coil. A co
1234Attic evaporator coil
· p. 218
The illustration shows an enclosed attic evaporator coil with return and supply ductwork, with arrows indicating airflow into and out of the unit. A primary condensate line connects to the unit and includes a trap; its c
1250Evaporator fan
· p. 221
The cross section shows a forced-air furnace with a blower below the furnace heat exchanger and an A-shaped evaporator coil in the plenum above it. Arrows show return air entering near the blower and moving upward throug
1239Leaking condensate tray
· p. 219
The cross section shows an A-shaped air-conditioning evaporator coil and condensate tray above a furnace heat exchanger, with a blower below directing return air upward into the supply plenum. The tray is identified as o