Related illustrations
1820Kickout prevents siding/wall damage
· p. 328
The illustration shows a shingle roof meeting a stucco wall along a sloping roof-to-wall intersection. Step flashing runs along the intersection, with the stucco wall acting as counter flashing over the vertical flashing
1776Kickout prevents siding/wall damage
· p. 318
The illustration shows a shingled roof meeting a stucco sidewall, with step flashing along the sloped roof-to-wall intersection. The stucco overlaps the upright flashing legs and is labeled as acting as counter flashing.
1820.6Missing kickout flashing
· p. 329
The illustration shows a sloped shingle roof terminating against a wall that continues past the roof edge. Portions of the lower shingles and siding are omitted to expose the wall sheathing paper or house wrap, eave prot
0073Roof/sidewall flashings
· p. 20
The illustration shows a shingled sloping roof meeting a stucco-clad sidewall, with an enlarged detail of the step flashing at the junction. Individual flashing pieces are interwoven with the shingle courses and overlap
0074Roof/sidewall flashings
· p. 21
The illustration shows a shingled roof meeting a stucco-clad sidewall, with an enlarged detail of the step flashing installation. Individual bent flashing pieces interleave with the shingle courses and extend up the wall
1777Exterior inspection strategy for EIFS
· p. 320
The illustration identifies inspection priorities for exterior insulation and finish systems (EIFS) using a roof-to-wall detail, a deck connection view, and an overview of a clad house. The roof detail shows step flashin